Advertisement

Warning: The Product ID should ONLY be modified by qualified service
personnel. This value should always match the Product ID located on the
chassis.
Enter the product ID and press the Enter key.
8.
Press the Esc key to close the menu.
9.
Press the Esc key to exit RBSU.
10.
Press the F10 key to confirm exiting RBSU. The server automatically reboots.
11.

HPE 550 W power supply

To remove the component:
Unlock and remove the tower bezel
1.
Power down the server (on page 23).
2.
Access the product rear panel.
3.
Release the power cord from the strain relief clip.
4.
Remove all power:
5.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Place the server on a sturdy, level surface.
6.
Remove the access panel (on page 24).
7.
Prepare the server for removal of the existing power supply:
8.
Remove all server components that block access to the power supply cables and screws.
a.
Disconnect all server cables that block access to the power supply cables and screws.
b.
Disconnect all power supply cables from the system board and drive cage.
c.
In a tower server, remove the existing power supply:
9.
("Remove the tower
bezel" on page 23).
Removal and replacement procedures 56