System Installation

PCB Layout

Cut R37 to reduce
volume
External
sounder
connections
Zone
connections
Leads to
transformer
Bell Fuse
This 1 Amp fuse protects the supply to the external
sounder/bell.
Aux Fuse
This 1 Amp fuse protects the supply to devices power
from the auxiliary 12V terminals.
Speaker Volume R37
Cut R37 to reduce the volume of the extension
loudspeakers.
Factory Restart Pins
If these pins are shorted during power-up all system
programming data is restored to the factory default
values, see page 6 for defaults.
Home Inhibit Link
When the link is open the (Alm-) terminal activates when
an alarm occurs during a full or part set condition. When
the link is closed the [ALM-] terminal activates only if an
alarm occurs during a full set condition.
496522 Issue A
Tamper switch
1
2
UNSET
1
4
7
HOME
A.C.
Figure 1. TS400 & TS410 Connection Diagram
3 of 10
Indicator LEDs
HOME ALM
INHIBIT
3
4
5
TAMP
F/E
FACTORY
RESTART
2
3
5
6
8
9
0
AWAY
Zones 1 - 5 Indicator LEDs
These red indicator LEDs indicate the alarm status of
zone 1 - 5. Note these are not fitted on the TS410.
Unset Indicator LED
This green indicator LED is used to indicate the status of
the system set or unset. It also flashes when the mains
power is removed or when the user selects the user
program mode.
Tamp Indicator LED
This red LED is used to indicate a system tamper alarm,
it also flashes when the engineer program mode is
selected. Note this is not fitted on the TS410.
F/E Indicator LED
This red LED is used to indicate the status of the final exit
zone. Note this is not fitted on the TS410.
TS400 & TS410
Home alarm
inhibit link
Factory Restart Pins
Remote Keypad
Interface Connector
Keypad
(Not fitted on TS410)
TS400 & TS410