2. When material handling is not operated (spool in the neutral position)
When a pressure is applied from the port P
The pressure compensating mechanism is inactive because solenoid c1 is not activated.
When the pressure compensating mechanism is inactive (sectional view of inlet section)
Main flow/excess flow
Pilot flow
Port T1
(g)
E
Port P
(c)
Solenoid c1
Non-leak valve
Q