When pressure compensation mechanism OFF
When solenoid C1 is not energized and the non-leak valve is open, the pressure oil from chamber (c)
flows through orifice Q, then returns to the tank via chamber (g). Now chamber (c) has the same
pressure as the tank, so all the pressure oil from port P returns to the tank via part E.
When the pressure compensating mechanism is inactive (sectional view of inlet section)
Main flow/excess flow
Pilot flow
Port T1
(g)
E
Port P
(c)
Solenoid c1
Non-leak valve
Q
9-11