3.2 Fuel Control Link - Install

3.2.1 Control Link Lever - Install
(1) Install the link lever with ball bearing, snap ring and end plate to the bracket.
(2) Set the governor output shaft at "0" angle (fuel decreasing side) and the specified angle of governor lever, then engage the
serrated portion of the shaft.
3.2.2 Fuel Control Link - Install and Adjust
Rack control lever
Fuel injection pump rack
Distance from the end of fuel
injection pump to the rack end:
68 ± 0.5 mm [2.68 ± 0.02 in.]
Rack "0": 65 mm [2.60 in.]
Play: approx. 3 mm [0.12 in.]
Toho Seisakusho SG4017 actuator spec
Woodward DYNA 8000 Actuator spec
Woodward PSG governor spec
Governor lever
Stop lever
Woodward PSG governor spec
10°
10°
Fuel Control Link - Install and Adjust
10°
Control link
65 ± 0.7 mm
[2.56 ± 0.028 in.]
Woodward ProAct actuator spec
Woodward EG-3P governor spec
Chapter 8 FUEL SYSTEM
Ball bearing
Link lever
End plate
Snap ring
Bracket
35°
8-43

Advertisement

Table of Contents
loading

This manual is also suitable for:

S6r2 series

Table of Contents