4.3.2.3.

Triggered mode without overlap

This mode gives lower FPS compared to Free-Run mode and lower FPS than Exposure Overlapped with Data Readout mode.
Sensor timing in Exposure Overlapped with Data Readout Mode
figure 4-2, acquisition mode – triggered without overlap
In this mode the timing depends on sum of:
Input transition time (t
o Digital Input Delay - time for changing internal circuit to active state. It is constant for each camera model.
o Input Debouncing Time - time for stabilizing uneven input signals (e.g. from mechanical switches). This time can be can
be set using xiAPI with parameters XI_PRM_DEBOUNCE_EN and XI_PRM_DEBOUNCE_T0 on some cameras. Default 0.
Exposure time (see ET above).
Data Readout time (see t
Typical times for selected camera models
Camera Model
DownS
MQ013xG-E2
any
table 4-4, trigger mode w/o overlap, timing
Notes:
N1: V(Input)=15V
N2:
in model name means all available models (M, C, R)
x
Description:
DownS = Current camera DownSampling (XI_PRM_DOWNSAMPLING)
t
= Trigger (Digital Input) to Strobe (Digital Output) (on some models is listed: Off->On change / On->Off change)
eio
t
= Strobe (Sensor) to Digital Output (on some models is listed: Off->On change / On->Off change)
exp
t
= Start of exposition to Exposure Active Digital Output
expo
LC
= Current Line Count (XI_PRM_ HEIGHT)
BW
= Bandwidth Factor for maximum bandwidth this is 1 when the bandwidth will be lower BWF will rise (TBD)
t
= Current Exposure Time set (XI_PRM_EXPOSURE)
exps
Conditions: XI_PRM_DEBOUNCE_EN=0 (off).
Minimum trigger period (T
Minimum trigger period can be calculated using the following formula:
xiQ - Technical Manual Version 1.0
), depends on:
itr
above)
rd
t
[µs]
t
[µs]
itr
exp
1.4
29
)
trig_min
t
[µs]
t
[µs]
t
eio
expo
rd
19/238
-10
400+16.6*BWF*LC
Notes
[µs]
N1, N2
61