3.8.4.4.6.
Output Wiring Example: Driving the trigger input of a strobe controller
The digital output can be used to drive a strobe controller according to the table below.
Driving the trigger input of a strobe controller
Trigger
Opto-isolated
polarity
controller input
Positive
Yes
edge
Negative
Yes
edge
Positive
No
edge
Negative
No
edge
table 3-29, digital output, wiring examples
3.8.4.5.
Digital Output – Timing
Typical input delay between FPGA_Output to Digital Output
Edge Type
Typ. delay [μs]
Off -> On
On -> Off
table 3-30, digital output, typical timing
Note: Measured at conditions: V
Output delay depending on output current:
Output current
OFF->ON
2mA
0.55μs
5mA
0.55μs
10mA
0.55μs
25mA
0.55μs
table 3-31, digital output, current depending timing
Note: Measured at conditions: V
xiQ - Technical Manual Version 1.0
Output
Wiring
delay
0.5µs
figure 3-33
0.5µs
figure 3-35
155µs
figure 3-36
0.5µs
figure 3-36
0.5
155
=18V, T
=27°C
OUTPUT
AMBIENT
ON->OFF
184μs
182μs
133μs
113μs
=11V, T
=25°C
OUTPUT
AMBIENT
Description
Not recommended in cases when short delay time is required.
Output delay is much longer than in other wiring examples. Use
external pull up in case that no pull up at controller input is
used.
Note that external pull up is not used in this case. Assume that
internal pull up at the controller input is used.