Recalibration procedure for banknotes and coins
Please note: Do not use the calibration function in the Safescan 6155 to calibrate coin rolls and money
packages. Coin rolls and Money packages should be calibrated via Safescan PC software only.
Recalibration procedure for the coin cup
When the factory supplied coin cup is damaged or you wish to use another coin cup, this function modifies the
default weight for the coin cup stored in the weight table. The procedure is the same as for banknotes and coins as
described above.
• Press and hold the
The screen will display CAL and 20x and the denomination 0.01.
• Use the
keys to select the coin cup calibration function. The screen will display: CAL, cup and 1x.
• Place the new cup or the damaged cup on the machine. The machine will make a beep.
• Press the
key to store the new cup weight in the weight table.
• Press the
key to exit the recalibration function.
9.0 RETURnInG TO FaCTORY DEFaUlT SETTInGS
This function resets the machine and reloads factory default settings.
This function will reset all user modified settings and will restore the original weight table for all currencies.
• Press and hold the
confirm factory default settings are restored. The machine is ready for use.
10. aUTO POwER OFF
When the machine is not used for 10 minutes, the power will be switched off automatically.
11. COnnECT wITh PC
Connect the USB cable (included in the box) to the device and the PC. Press
12. PRInTInG COUnTInG RESUlTS wITh a ThERMal PRInTER
Connect a serial cable (optional) to the RJ45 connector of the device and the printer. Press
print the counting results.
9
• Press and hold the
the recalibration function. The screen will display: CAL, 20x and the
smallest denomination.
• Use the
• Place 20 banknotes or coins on the machine. For coins, make sure to use
the coin cup. The machine will make a beep.
• Press the
• Press the
and
key for 3 seconds. This will activate the recalibration function.
and
key for 3 sec. The machine will make 3 beeps followed by 2 short beeps to
and
key for 3 seconds. This will activate
keys to select the denomination you wish to recalibrate.
key to store the recalibration result in the weight table.
key to exit the recalibration function.