Lug Assembly; High Current Wiring Recommendations; Battery Cables (B+, B-); High Current Connections And Wiring Guidelines - Curtis 1298 User Manual

Integrated traction & hydraulic system motor controller
Table of Contents

Advertisement

Curtis 1298 Manual,
11
OS
HIGH CURRENT CONNECTIONS
There are six high-current terminals, identified on the controller housing as
,
,
,
,
, and
B+
B-
PUMP
U
V

Table 1 High Current Connections

TERMINAL
B+
B-
PUMP
U
V
W

Lug assembly

Six aluminum M6 terminals are provided. Lugs should be installed as follows,
using M6 bolts sized to provide proper engagement (see diagram):
• Place the lug on top of the aluminum terminal, followed by
a high-load safety washer with its convex side on top. The
washer should be a
• If two lugs are used on the same terminal, stack them so the
lug carrying the least current is on top.
• Tighten the assembly to 10.2 ±1.1 N·m (90 ±10 in-lbs).

High current wiring recommendations

Battery cables (B+, B-)

These two cables should be run close to each other between the controller
and the battery. Use high quality copper lugs and observe the recommended
torque ratings. For best noise immunity the cables should not run across the
center section of the controller. With multiple high current controllers, use a
star ground from the battery
Pump wiring (PUMP)
Cable lengths should be kept as short as possible. Use high quality copper lugs
and observe the recommended torque ratings. For best noise immunity the motor
2 — INSTALLATION & WIRING:
.
W
FUNCTION
Positive battery to controller.
Negative battery to controller.
Pump motor.
Motor phase U.
Motor phase V.
Motor phase W.
416320, or equivalent.
SCHNORR
terminal.
B-
High Current Connections