Permanent Parameter Storage / Factory Reset; Persistent Ip Address - Photon Focus MV1-D1280-L01-3D05 Series User Manual

Cmos camera with gige interface
Table of Contents

Advertisement

7 Software

7.8 Permanent Parameter Storage / Factory Reset

The property UserSetSave (in category UserSetControl) stores the current camera settings in the
non-volatile flash memory. At power-up these values are loaded.
The property UserSetSave (in category UserSetControl) overwrites the current camera settings
with the settings that are stored in the flash memory.
The command CameraHeadFactoryReset (in category PhotonfocusMain) restores the settings of the
camera head
The property CameraHeadStoreDefaults (in category PhotonfocusMain) stores only
the settings of the camera head in the flash memory. It is recommended to use
UserSetSave instead, as all properties are stored.
The calibration values of the FPN calibration are not stored with UserSetSave (or
CameraHeadStoreDefaults). Use the command Correction_SaveToFlash for this (see
Correction_SaveToFlash).

7.9 Persistent IP address

It is possible to set a persistent IP address:
1.
Set GevPersistentIPAddress (in category TransportLayerControl) to the desired IP address.
2.
Set GevPersistentSubnetMask (in category TransportLayerControl) to the sub net mask.
3.
Set GevCurrentIPConfigurationPersistent (in category TransportLayerControl) to True.
4.
Set GevCurrentIPConfigurationDHCP (in category TransportLayerControl) to False.
5.
The selected persistent IP address will be applied after a reboot of the camera.
.
96 of 117
MAN073 12/2016 V1.0

Advertisement

Table of Contents
loading

Table of Contents