Electrical Characteristics; Power And Ground Connection For Gige G2 Cameras - Photon Focus MV1-D1280-L01-3D05 Series User Manual

Cmos camera with gige interface
Table of Contents

Advertisement

6.5 Electrical Characteristics

Parameter
Camera Power Supply
Camera Control Input Single Ended
Camera Control Input RS422 Receiver Sensitivity
Camera Control Input RS422 Maximum Common Mode Range
Camera Control Input RS422 Maximum Differential Input Level
Camera Control Input RS422 Minimum Differential Input Level
ISO power RS-422
ISO power HTL
Table 6.3: Electrical Characteristics

6.6 Power and Ground Connection for GigE G2 Cameras

The interface electronics is isolated from the camera electronics and the power supply
including the line filters and camera case. Fig. 6.2 shows a schematic of the power and ground
connections in the G2 camera models.
.
MAN073 12/2016 V1.0
6.5 Electrical Characteristics
Value
+12 V (-10%) ... +24 V (+10%)
+5 V ... +30 V
+/- 200 mV
-7 V ... +7 V
10 V
2 V
5 V (-10%) ... 24 V (+10%)
10 V (-10%) ... 30V (+10%)