Shutter-Select Mode With External Trigger - JAI LQ-050CL User Manual

Rgb color & nir 4ccd line scan camera
Table of Contents

Advertisement

 If using individual exposure, the EEN signal represents the channel with the longest
exposure time
 The longest shutter operation is the same as the set trigger interval.
 If one-push auto white balance is used, using the shutter (command AH) or using the
gain (command AW) depends on applications. If the auto white balance switch located
on the rear panel is used, only the gain is effective.
LVAL
EEN
φ PG
φ TG
φ AB_Rch
φ AB_Gch
T1 (Gch)
φ AB_Bch
T1 (Bch)
φ H1
φ H2
DVAL
Dat a
Note: Exposure time(ns) =25ns x (Repetition cycle(ck) –(T1 +21)ck)
EEN is output in coincident with the timing of the longest exposure channel
Fig. 16
Shutter-Select mode with internal line rate generator (and individual exposure)
6.2.4

Shutter-Select mode with external trigger

This mode allows the user to have full control of the exposure time, by programming a
timing generator, while the line rate is controlled by an external trigger signal. The
camera can accept an external trigger through the Camera Link connector or though the
12-pin Hirose connector.
To use this mode:
Set function
Important note:
LQ-050CL
T1 (Rch)
30ck
30ck
30ck
Trigger
Trigger origin, external
Individual R, G and B exposure
Programmable exposure
A
Effective Video
TR=1
TG=1
EI=0(individual)
EI=1(interlocked with G)
PER/PEG/PEB/PEIR=2 to {trigger
Interval ― 60clk(1.5μs)} in 1
clock(25ns) step (50ns to 14.438ms)
20
512