Wire Connection - Optex AX-70TN Installation Manual

Photoelectric detector
Hide thumbs Also See for AX-70TN:
Table of Contents

Advertisement

3. Wiring
Use wires in compliance with the following conditions:
1) Wire diameter: φ4 - 7mm
2) When using any other wires than the above, seal the wiring port
with a waterproof agent (silicon, etc.) to prevent water from coming
in through the gap.
3) Number of wires: 3 (max.)
Wiring Hole 1
3 wires can be accommodated in a unit.
Lead-in wire should be as below.
*Wiring hole 2 needs to be punched with a screw driver, etc.
* To have the wiring hole 3, wiring port needs to be cut with a cutter knife,
etc. After inserting the wire, seal the wiring port with a waterproof material
like silicon for leakage prevention.
4. Mount the unit base
Side view of the waterproof plug
Connect the terminals with reference to "4. WIRE
CONNECTION" and slide the unit base into the mounting
plate from above, then fasten the unit base mounting
screws to x the unit base. Then, push in the waterproof
plug up to the broken line shown in the gure above.

4. WIRE CONNECTION

Connect respective wires to the terminals shown in the following gure.
1. Terminal
[AX-70/130/200TN]
Alarm output (N.C.)
< Receiver >
Non-voltage contact output
Contact capacity: 28VDC and 0.2A (max.)
Tamper output
(It opens when cover is removed)
Power input
10.5 to 28VDC
ALARM TAMPER
[AX-100/200TF]
Alarm output: (N.C./N.O.) switch (In case of using N.O., contact is not reversed when power supply is off.)
< Receiver >
Non-voltage contact output
Contact capacity: 28VDC and 0.2A (max.)
Tamper output
(It opens when cover is removed)
Power input
10.5 to 28VDC
N.C./
COM. N.O. TAMPER
Use the COM. terminal for both alarm
output and D.Q. circuit.
N.C.
Environmental Disquali cation (N.C.)
Non-Voltage contact output
Contact capacity : 28VDC and 0.2A (max.)
Cutting
Wiring Hole 2
Waterproof Plug
Unit Base
Lock Screw
Push in up to
this position
Note: Non-Voltage contact output
Resistive load only
Non-voltage contact output
Contact capacity: 28VDC and 0.2A (max.)
Non-voltage contact output
Contact capacity: 28VDC and 0.2A (max.)
Figure 1
Wiring guide should be as below.
Knockout needs to be opened with a nipper, etc.
5. Alignment and walk test
Screwdriver
< Transmitter >
Tamper output : (BE) Model only
(it opens when cover is removed)
Non-voltage contact output
Contact capacity: 28VDC and 0.2A (max.)
Power input
10.5 to 28VDC
TAMPER
N.C. / N.O. selection Swich
OFF
ON
N.C. ⇔ N.O.
< Transmitter >
Tamper output : (BE) Model only
(it opens when cover is removed)
Non-voltage contact output
Contact capacity: 28VDC and 0.2A (max.)
Power input
10.5 to 28VDC
TAMPER
Figure 2
Figure 3
Align the optical axis to the maximum
receiving level according to "5-1.
OPTICAL ALIGNMENT". Then, check
for the operation with reference to "6.
WALK TEST".
Put the cover and tighten the
cover lock screw.
Make sure that the cover edge
has reached the line prepared
on the side of the unit base
(See the gure left)
Line
2. Wiring distance between power
supply and detector
・ Ensure that the wiring distance from the
power supply is within the range shown in
the table on the right.
・ When using two or more units on one wire,
the maximum length is obtained by dividing
the wire length listed below by the number
of units used.
Wire size
AWG22
1600ft. ( 500m )
( 0.33mm
2
)
AWG20
2200ft. ( 700m )
2
( 0.52mm
)
AWG18
3600ft. ( 1100m )
2
( 0.83mm
)
AWG16
5500ft. ( 1700m )
2
( 1.31mm
)
"For UL Listed applications, the units shall be connected to a UL
Listed control unit or Listed Burglar Power Supply capable of
providing a minimum of 4 hours standby power."
Do not exceed the voltage
or current rating speci ed
for any of the terminals
during installation,
WARNING
doing so might cause re
or damage to the devices.
Knockout
Knockout
Power supply voltage
12VDC
24VDC
7800ft. ( 2400m )
11400ft. ( 3500m )
18000ft. ( 5500m )
26200ft. ( 8000m )