Additional Master Configuration

Configuring an External IPv4 Address for the Stack

Locating an External Stack Interface

© Copyright IBM Corp. 2011
Once the stack links are connected, access the internal management IP interface of
the Master switch (assigned by the management system) and complete the
configuration.
In addition to the internal management IP interface assigned to the Master switch by
the management system, a standard switch IP interface can be used for connecting
to and managing the stack externally. Configure an IP interface with the following:
Stack IPv4 address and mask
IPv4 default gateway address
VLAN number used for external access to the stack (rather than the internal
VLAN 4090 used for inter-stack traffic)
One completed, stack management can be performed via Telnet or BBI (if enabled)
RS G8000(config)# ip gateway <gateway number> address <gateway IPv4 address>
RS G8000(config)# ip gateway <gateway number> enable
RS G8000(config)# interface ip <IP interface number>
RS G8000(config-ip-if) ip address <stack IPv4 address>
RS G8000(config-ip-if) ip netmask <IPv4 subnet mask>
RS G8000(config-ip-if) vlan <VLAN ID>
RS G8000(config-ip-if) enable
RS G8000(config-ip-if) exit
from any point in the configured VLAN, using the IPv4 address of the configured IP
interface.
In the event that the Master switch fails, if a Backup switch is configured (see
"Assigning a Stack Backup Switch" on page
stack will still be available. Otherwise, the administrator must manage the stack
through the internal management IP interface assigned to the Backup switch by the
management system.
If the IPv4 address and VLAN of an external IP interface for the stack is unknown,
connect to the Master switch using the IPv4 address assigned by the management
system, and execute the following command:
RS G8000(config)# show interface ip