Viewing Stack Connections; Binding Members To The Stack; Assigning A Stack Backup Switch - IBM RackSwitch G8000 Application Manual

A top-of-rack (tor) switch
Hide thumbs Also See for RackSwitch G8000:
Table of Contents

Advertisement

Viewing Stack Connections

Binding Members to the Stack

Assigning a Stack Backup Switch

156
RackSwitch G8000: Application Guide
To view information about the switches in a stack, execute the following command:
RS G8000(config)# show stack switch
Stack name:
Local switch is the master.
Local switch:
csnum - 1
MAC - 00:00:00:00:01:00
Switch Type - 9
Chassis Type - 99
Switch Mode (cfg) - Master
Priority - 225
Stack MAC - 00:00:00:00:01:1f
Master switch:
csnum - 1
MAC - 00:00:00:00:01:00
Backup switch:
csnum - 2
MAC - 00:22:00:ad:43:00
Configured Switches:
--------------------------------
csnum
MAC
--------------------------------
C1
00:00:00:00:01:00
C2
00:22:00:ad:43:00
C3
00:11:00:af:ce:00
Attached Switches in Stack:
-------------------------------------
asnum
MAC
-------------------------------------
A1
00:00:00:00:01:00
A2
00:11:00:af:ce:00
A3
00:22:00:ad:43:00
You can bind Member switches to a stack csnum using either their asnum or MAC
address :
RS G8000(config)# stack switch-number <csnum> mac <MAC address>
-or-
RS G8000(config)# stack switch-number <csnum> bind <asnum>
To remove a Member switch, execute the following command:
RS G8000(config)# no stack switch-number <csnum>
To define a Member switch as a Backup (optional) which will assume the Master
role if the Master switch fails, execute the following command:
RS G8000(config)# stack backup <csnum>
asnum
A1
A3
A2
csnum
State
C1
IN_STACK
C3
IN_STACK
C2
IN_STACK

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents