Configuring Rmon History - IBM RackSwitch G8000 Application Manual

A top-of-rack (tor) switch
Hide thumbs Also See for RackSwitch G8000:
Table of Contents

Advertisement

Configuring RMON History

© Copyright IBM Corp. 2011
Perform the following steps to configure RMON History on a port.
1. Enable RMON on a port.
RS G8000(config)# interface port 1
RS G8000(config-if)# rmon
RS G8000(config-if)# exit
2. Configure the RMON History parameters for a port.
RS G8000(config)# rmon history 1 interface-oid
1.3.6.1.2.1.2.2.1.1.<x>
RS G8000(config)# rmon history 1 requested-buckets 30
RS G8000(config)# rmon history 1 polling-interval 120
RS G8000(config)# rmon history 1 owner "rmon port 1 history"
where <x> is the number of the port to monitor. For example, the full OID for port
1 would be:
1.3.6.1.2.1.2.2.1.1.1
3. View RMON history for the port.
RS G8000(config)# show rmon history
RMON History group configuration:
Index
IFOID
-----
-----------------------
1
1.3.6.1.2.1.2.2.1.1.1
Index
-----
----------------------------------------------
1
rmon port 1 history
Interval
Rbnum
--------
-----
120
30
Owner
Chapter 28. Remote Monitoring
Gbnum
-----
30
335

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents