2. If you are installing the IpChannel Bank in a 19-inch rack, go to step 4. Otherwise, place the IpChannel
Bank at the desired location.
3. Go to section

"Connecting cables"

4. Install the rack mounting ears onto the IpChannel Bank using the mounting hardware provided.
5. Place the IpChannel Bank at the desired position in the rack.
6. Secure the IpChannel Bank in position with the mounting screws.
7. Go to section

"Connecting cables"

Connecting cables
This section describes installing the interface, power, and ground cables in the following order:
CAUTION
1. Installing the RJ-11 voice port (FXS) cable or cables (see section
2. Installing the 10/100 Ethernet port cable (see section
3. Installing the RS-232 console cable (see section
(DCE configured)"
4. Installing the power input (see section
WARNING

Connecting the FXS ports

The remote FXO devices are connected to the IpChannel Bank via the RJ-21X cable. Consult
page 55
in order to connect the FXO devices to the selected FXS port on the IpChannel Bank.
1. Connect the RJ-21X connector of the cable into the 64-pin or 50-pin RJ-21X receptacle on the IpChannel
Bank. The pin count will depend on the IpChannel Bank that you ordered.
2. The other end of the cable has 25 non-terminated twisted-pairs for connection to punch-down blocks.
Select the twisted-pairs which will be used for
3. Select and attach the appropriate twisted-pair from each FXO device on punch-down blocks for connec-
tion to the chosen port on the IpChannel Bank.

Connecting the Ethernet ports

The IpChannel Bank has dual 10/100 Ethernet interfaces. One is for the WAN connection. The other is for
connecting to your Ethernet LAN. The Ethernet ports will auto-sense the correct speed of the local LAN and
Installing the IpChannel Bank
on page 28
on page 28
The
cables must be acceptable for external use
Interconnecting
and must be rated for the proper application with respect to volt-
age, current, anticipated temperature, flammability, and
mechanical serviceability.
on page 30)
"Connecting power"
Do not work on the system or connect or disconnect cables during periods of
lightning activity.

"Connecting the FXS ports"