6.2. Opto-isolated Interface
The control interface of the C3 GigE Vision
camera series has opto-isolated inputs and
outputs, providing galvanic separation between
the camera's inputs/outputs and peripheral
equipment. In addition to galvanic separation,
the opto-isolated inputs and outputs can cope
with a wide range of voltages; the voltage
range for inputs is +3.3V to +24V DC whereas
outputs will handle +5V to +24V DC.
The figure at the right shows the functional
principle (opto-coupler) of the opto-isolated
inputs/outputs.
6.2.1 Recommended External Input circuit diagram for customer
6.2.2 Recommended External Output circuit diagram for customer
AM-200GE / AB-200GE
Fig.10
External Input Circuit, OPT IN 1 and 2
Fig.11
External Output Circuit, OPT OUT 1 and 2
Fig.9
- 16 -
Opto-coupler