5.3.3 Work area
a) Ensure that the workplace is well ventilated. Ex-
posure to dust at a poorly ventilated workplace may
result in damage to the health.
b) Keep the workplace tidy. Objects which could
cause injury should be removed from the work-
ing area. Untidiness at the workplace can lead to
accidents.
c) If the work involves breaking right through, take
the appropriate safety measures at the opposite
side. Parts breaking away could fall out and / or fall
down and injure other persons.
d) Approval must be obtained from the site engineer
or architect prior to beginning the work. Work

6 Before use

CAUTION
Check the insert tool for damage or uneven wear each
time before use.
6.1 Fitting, positioning and removing the side
handle (accessory) 2
1.
Disconnect the mains plug from the power outlet.
2.
Open the clamping band and push it on to the neck
of the tool.
3.
Release the knob by turning it and then remove it.
4.
Remove the hexagon-head bolt by pulling it out of
the grip unit.
5.
Push the grip unit onto the mount on the clamping
band.
NOTE Check that the teeth are in the correct posi-
tion.
6.
Reinsert the hexagon-head bolt.
7.
Fit the knob.
8.
Pivot the side grip into the desired position.
9.
Secure the side grip by tightening the knob.
on buildings and other structures may influence
the statics of the structure, especially when steel
reinforcing bars or load-bearing components are
cut through.
5.3.4 Personal protective equipment
The user and any other persons in the vicinity must
wear suitable eye protection, a hard hat, ear protec-
tion, protective gloves, safety footwear and respirat-
ory protection while the tool is in use.
10. To remove the side handle, follow the assembly
instructions but carry out the necessary steps in the
reverse order.
NOTE When fitting and positioning the side handle,
pay attention to the description enclosed with the
side handle.
6.2 Connecting the supply cord to the power
tool 3
CAUTION
The releasable electric connector may be connected
to the power tool only when it is clean and dry and
when under no voltage (i.e. disconnected from the
electric supply). Disconnect the supply cord plug from
the electric power outlet before disconnecting the
releasable supply cord connector from the power
tool or before cleaning it.
1.
Remove the supply cord from the cardboard box.
2.
Push the keyed releasable electric connector into
the socket on the power tool as far as it will go.
3.
While pushing it in under light pressure, turn the
keyed releasable electric connector in a clockwise
direction until it is heard to engage.
4.
Plug the supply cord into the power outlet.
6.3 Use of extension cords and generators or
transformers
See section "Description / use of extension cords".
en