DSX-1-to-DSX-1 Configuration

A-2
To connect two DSX-1-compatible units, configure the units as follows. Terminal
mode factory defaults are in bold (for Switchpack mode defaults, see Appendix C,
Switchpacks and Jumpers
Configuration
DSX-1-Compatible Unit
Option
(Customer Premises)
Card Type
CP (default)
Loops Enabled
Dual (Loops A & B) or
Single (Loop A)
T1 Line Encode
B8ZS or AMI
Framing
D4, Extended Superframe,
or Unframed
Line Build-Out
Enter 5 at the Config
command prompt. Select
from the following options:
1) 0 to 133 ft
2) 133 to 266 ft
3) 266 to 399 ft
4) 399 to 533 ft
5) 533 to 655 ft
October 1997
).
DSX-1-Compatible Unit
(Central Site)
CO
Must be same as CP side
Must be same as CP side
Must be same as CP side
Enter 5 at the Config command
prompt. Select from the following
options:
1) 0 to 133 ft
2) 133 to 266 ft
3) 266 to 399 ft
4) 399 to 533 ft
5) 533 to 655 ft
7924-A2-GB20-30