Front Panel Leds; Dsx-1-Compatible Unit - Paradyne HotWire 7924 User Manual

Standalone t1 hdsl termination unit
Hide thumbs Also See for HotWire 7924:
Table of Contents

Advertisement

Monitoring the Unit

Front Panel LEDs

DSX-1-Compatible Unit

6-6
Upon power up, the first three LEDs blink in sequence, indicating a successful
start configuration. The green PWR LED lights whenever power is applied to the
board. Loop LEDs blink until the loop has been synchronized and then remain off.
T1 HDSL
TERMINAL
LED
Meaning
Local
ON: The local T1 interface has a loss of signal.
Remote
ON: The remote T1 interface has a loss of signal.
Loop Bk
ON: A loopback has been initiated for testing the equipment connected to
this unit. Refer to Chapter 7,
PWR
ON: Power is applied to the unit.
FAIL
ON: The processor has halted and repairs are required.
Loop A
ON: HDSL Loop A has failed.
Blinking: HDSL Loop A is synchronizing with the far-end unit (such as
when the units are coming up after a reset). If the LED blinks for more
than 60 seconds, loss of signal has occurred.
Off: Loop A is enabled and synchronized.
Loop B
ON: HDSL Loop B has been disabled (only Loop A is in use) or has
failed.
Blinking: HDSL Loop B is synchronizing with the far-end unit (such as
when the units are coming up after a reset). If the LED blinks for more
than 60 seconds, loss of signal has occurred.
Off: Loop B is enabled and synchronized.
October 1997
NETWORK
SYSTEM
HDSL
Testing ,
for more information.
TM
TM
7900
7900
97-15312
7924-A2-GB20-30

Advertisement

Table of Contents
loading