Troubleshooting - Paradyne COMSPHERE 3800PLUS User Manual

Paradyne comsphere modems user's guide 3800plus
Hide thumbs Also See for COMSPHERE 3800PLUS:
Table of Contents

Advertisement

Overview
Appendix B,
Result
Codes, points out basic problems
that can occur when operating a 3800Plus modem. Use
Tables C-1 through C-6 to check out these problems. If
you are having data communication difficulties, such as
Symptom
Modem did not pass power-up self-test
Power LED does not light
LCD does not display
A problem is suspected after the
power-up self-test
3980-A2-GB30-40

Troubleshooting

periodic character loss, random errors, or constant format
errors, use the loopback tests described in Chapter 7,
Branch. With these tests you can usually isolate the fault
in your system by using the process of elimination. If
problems continue to occur, contact your service
representative.
Table C-1
Modem Integrity
Contact your service representative.
Make sure the modem's ON/Off switch is in the ON position.
Make sure the ac power transformer is connected to the ac power receptacle.
If Power LED and/or LCD do not operate, contact your service representative.
Perform a self-test via the modem's DCP or type AT&T9 if using AT
commands.
Perform a local analog loopback with a Pattern test. If the modem consistently
registers errors, contact your service representative.
If the modem passes the above tests and a problem still exists, then the
problem is likely not with your modem.
October 1998