AT Command
S74
Network Position Identification
Register identifies each modem as either a control or tributary modem.
Register has the following values:
0=Tributary
1=Control
Factory setting is Tributary for the 3810 Plus .
Factory setting is Control for the 3811 Plus .
S75
Network Management Address
Register determines the modem's network address. This address is used
when accessing the modem from the NMS.
Enter a value from 0 (network address 001) to 255 (network address 256).
The factory default templates do not affect S75.
S76
Autorate (Dial Line)
Register determines if Autorating is used on dial lines when connected in
V.32bis or V.34 mode.
Register has the following values:
0=Enable
1=Disable
2=Start at 4800 bps
3=Start at 9600 bps
Factory setting is Enable.
S77
DTR Alarm Reporting
Register determines whether an alarm is sent to the NMS controller when
the DTR signal has been off for more than 10 seconds.
Register has the following values:
0=Disable
1=Enable
The factory default templates do not affect S77.
S78
Automode (Dial Line)
Register allows the modem (when operating on dial lines) to automatically
detect and connect to the remote modem's modulation scheme.
If the modem is in a modem pool attached to a System 85 Private Branch
Exchange (PBX), S78 should be set to 2. This modifies parameters used
during connection to the PBX.
Register has the following values:
0=Enable
1=Disable
2=System 85
Factory setting is Enable.
3980-A2-GB30-40
Table 13-2
(12 of 15)
3800 Plus S-Registers
Description
October 1998
AT Command Set and S-Registers
Front Panel Branch
Configure\Edit\Misc
Configure\Edit\Dial
Configure\Edit\
Dial Line
Configure\Edit\Misc
Configure\Edit\
Dial Line
13-29

Advertisement

Table of Contents
loading

Table of Contents