COMSPHERE 3800Plus Modems
AT Command
&T n
Tests
&T0
Abort. Stops any test in progress.
&T1
Local Analog Loop.
&T2
Pattern. Transmits and receives a 511 Bit Error Rate Test (BERT).
&T3
Local Digital Loopback test.
&T4
Enables Receive Remote Loopback Response configuration option.
&T5
Disables Receive Remote Loopback Response configuration
option.
&T6
Remote Digital Loopback test.
&T7
Remote Digital Loopback with Pattern.
&T8
Local Loopback with Pattern.
&T9
Self-Test.
&V n
View Configuration Options
Displays each configuration group within the Active (Operating), Active
(Saved), Customer 1, and Customer 2 configuration areas as well as the
telephone numbers stores in directory locations 1–10.
The output of the &V command can be saved to a file and printed (using
your communications software), providing both a record of your
configuration and a worksheet for configuration enhancements.
&V0
Active (Operating) configuration options.
&V1
Active (Saved) configuration options.
&V2
Customer 1 configuration options.
&V3
Customer 2 configuration options.
&V4
Directory locations 1–10.
&W n
Write (Save to Memory)
Saves the current configuration options in Active (Operating) to one of
three configuration areas. This is required to make any configuration
changes permanent.
&W0 Saved to Active(Save).
&W1 Saved to Customer 1.
&W2 Saved to Customer 2.
&X n
Transmit Clock Source
&X0 Internal. Modem provides transmit clock source for synchronous
data (Pin 15).
&X1
External. Modem derives external transmit clock source provided on
Pin 24 for synchronous data.
&X2
Receive Clock Loop. Modem derives transmit clock source from
receive signal for synchronous data (Pin 17).
&Z n=x
Store Telephone Numbers
Modem saves the telephone numbers and dial command modifiers (if any)
entered for x (up to 40 characters in length) in Directory Location n (1–10).
For example, the command AT&Z1=5551234 stores the telephone number
555-1234 into directory location 1.
To clear a telephone number from a memory location, issue the
&Z n = x command without entering a telephone number.
13-12
Table 13-1