Paradyne 3800Plus Installation Instructions Manual

Zhone comsphere 3800plus modems: installation instruction
Hide thumbs Also See for 3800Plus:

Advertisement

COMSPHERE 3811 Plus Modem
Installation Instructions
Document Number 3980-A2-GZ41-20
June 1998
User's Guide
This document provides basic installation instructions
for the COMSPHERE 3811Plus (Model 3981) modem.
For complete configuration and operation instructions,
refer to the COMSPHERE 3800Plus Modems User's
Guide (Document Number 3980-A2-GB30).
Contact your local sales representative, service
representative, or distributor directly for any help needed.
For additional information concerning warranty, sales,
service, repair, installation, documentation, training,
distributor locations, or Paradyne worldwide office
locations, use one of the following methods:
Via the Internet: Visit the Paradyne World Wide
Web site at http://www.paradyne.com
Via Telephone: Call our automated call system to
receive current information via fax or to speak with a
company representative.
— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A., call 1-727-530-2340

Important Safety Instructions

1. Read and follow all warning notices and
instructions marked on the product or included in
the manual.
2. Slots and openings in the cabinet are provided for
ventilation. To ensure reliable operation of the
product and to protect it from overheating, these
slots and openings must not be blocked or
covered.
3. General purpose cables may be provided with this
product. Special cables, which may be required by
the regulatory inspection authority for the
installation site, are the responsibility of the
customer.
3980-A2-GZ41-20
TM
June 1998
4. When installed in the final configuration, the
product must comply with the applicable Safety
Standards and regulatory requirements of the
country in which it is installed. If necessary,
consult with the appropriate regulatory agencies
and inspection authorities to ensure compliance.
In addition, if the equipment is to be used with
telecommunications circuits, take the following
precautions:
Never install telephone wiring during a lightning
storm.
Never install telephone jacks in wet locations
unless the jack is specifically designed for wet
locations.
Never touch uninsulated telephone wires or
terminals unless the telephone line has been
disconnected at the network interface.
Use caution when installing or modifying telephone
lines.
Avoid using a telephone (other than a cordless type)
during an electrical storm. There may be a remote
risk of electric shock from lightning.
Do not use the telephone to report a gas leak in the
vicinity of the leak.
Government Requirements
Notice to Users of the United States Public
Switched Telephone Network
1. This equipment complies with Part 68 of the FCC
rules. On the equipment is a label that contains,
among other information, the FCC registration
number and ringer equivalence number (REN) for
this equipment. The label is located on the circuit
card assembly of the 3811Plus. If requested, this
1

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne 3800Plus

  • Page 1: Important Safety Instructions

    This document provides basic installation instructions for the COMSPHERE 3811Plus (Model 3981) modem. For complete configuration and operation instructions, refer to the COMSPHERE 3800Plus Modems User’s Guide (Document Number 3980-A2-GB30). Contact your local sales representative, service representative, or distributor directly for any help needed.
  • Page 2 information must be provided to the telephone company. 2. The Universal Service Order Code (USOC) for Permissive mode is RJ21X. The Canadian equivalent to the USOC is CA21A. 3. The Ringer Equivalence (REN) is used to determine the quantity of devices which may be connected to the telephone line.
  • Page 3 CAUTION Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. The Load Number for this equipment is on the label on the modem. The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device to prevent overloading.
  • Page 4: Equipment Warranty And Support

    command line or from a directory. An occurrence of the restriction is canceled when a different number is dialed, or when three minutes have elapsed. Equipment Warranty and Support Technical Support Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office...
  • Page 5 Status Alrm Test Dial Busy Serv Front Panel Spkr 3811 Plus 3980-A2-GZ41-20 EIA232/V.24 Faceplate Connector EIA232/V.24 Edge Card Connector Figure 1. 3811 Plus Modem June 1998 Rear Connector Plate Unused 496-14488-02...
  • Page 6 The COMSPHERE 3000 Series Carrier has 17 slots which can hold up to 16 modems and one SDU. The SDU is required when the modems in the carrier are controlled by an NMS, or when multiple carriers in a cabinet configuration are to be controlled by a single SDCP.
  • Page 7 Alrm LED on the faceplate lights up or flashes. It may be possible to run a diagnostic self-test from the SDCP. See Test Branch in the COMSPHERE 3800Plus Modems User’s Guide. Return to the rear of the carrier and tighten the rear connector plate.
  • Page 8: Select Factory Configuration Options

    Select Factory Configuration Options After the modem passes the power-up self-test, configure it for operation using one of the factory preset configurations. The 3811Plus modem has several factory preset templates that contain the proper configuration options (straps) for different environments. Modems are shipped from the factory with the Async Dial default configuration options stored in memory.
  • Page 9: Menu Structure

    Control Used to control the modem’s hardware and software functions. Remote Used to access and control a remote 3800Plus series modem. Security Used to control the modem’s dial access security. Appears only if the optional security feature is installed.
  • Page 10 Call_Setup Dial Answer Change_Directory Disconnect Dial_Standby Return_to_Dial Directory Locations 1 – 10 Does not appear in Remote Mode. (Rem_Digital_Loop, Loc_Digital_Loop, and Pattern appear if the secondary channel is used.) Some choices within this group may not appear depending upon how previous configuration options have been selected.
  • Page 11 from previous page Activ (Operating) Active (Saved) from previous page Leased_Line V42/MNP/Buffer Leased Mode Err Contrl Mode Modulation Sync Comp Mode LeasedLine Rate SDC Negotiation Autorate SDC Idle Fill Leased TX Level SDC BitEncoding Bad Ln Auto Orig SyncDTE CRC Rate Auto Orig SDC Delay Min Auto Redial...
  • Page 12 from previous page Control Speaker Make_Busy RemoveMakeBusy Reset Copyright 1998 Paradyne Corporation Remote Secondary Prim (data blckd) (ExitRem appears instead of Remote when using Remote Mode) EditPassWdTable Download Code Service_Line DiscServLine Does not appear in Remote Mode. (Rem_Digital_Loop, Loc_Digital_Loop, and Pattern appear if the secondary channel is used.) *3980–A2–GZ41–20*...

This manual is also suitable for: