COMSPHERE 3800Plus Modems
AT Command
S80
No Data Disconnect Trigger Signal
Register determines whether Pin 2 (transmit data) or Pin 3 (receive data)
of the modem's RS-232 serial interface is monitored so that the modem
can disconnect the call if there is no activity for a certain period. (See the
\T command.)
Register has the following values:
0=Transmit or Receive
1=Transmit only
2=Receive only
3=Transmit and Receive
Factory setting is 3.
S82
Autorate (Leased Line)
Register determines if Autorating is used on leased lines when connected
in V.32bis or V.34 mode.
Register has the following values:
0=Enable
1=Disable
Factory setting is Enable.
S83
MI/MIC Dialing
On Model 3811 Plus only, register determines if MI/MIC control leads can
be used to force the modem into the originate handshake after first dialing
a call.
Register has the following values:
0=Disable
1=Enable
Factory setting is Disable.
S84
AT Command Mode
Register determines how the modem responds to valid and invalid
AT commands.
Register has the following values:
0=Normal
1=No ERROR
2=No Strap or ERROR
Factory setting is Normal.
S85
Fast Disconnect
Register allows the modem to disconnect immediately after receiving a
disconnect command from a local DTE or its own diagnostic control panel.
Register has the following values:
0=Disable
1=Enable
Factory setting is Disable.
13-30
Table 13-2
(13 of 15)
3800 Plus S-Registers
Description
October 1998
Front Panel Branch
Configure\Edit\
Line Dialer
Configure\Edit
Leased Line
Configure\Edit\
Line Dialer
Configure\Edit\
DTE Dialer
Configure\Edit\
Line Dialer