AT Command
S62
V.25bis Coding
Register identifies to the modem the type of coding used by the DTE while
in V.25bis mode.
Register has the following values:
0=ASCII
1=EBCDIC
Factory setting is ASCII.
S63
V.25bis Idle Character
Register identifies to the modem the type of idle fill used by the DTE while
in V.25bis mode.
Register has the following values:
0=Mark
1=Flag
Factory setting is Mark.
S64
V.25bis New Line Character
Register identifies to the modem the type of line terminator used by the
DTE while in V.25bis mode.
Register has the following values:
0=Carriage Return and Line Feed
1=Carriage Return
2=Line Feed
Factory setting is carriage return and line feed (CR + LF).
S66
NMS Call Messages
Register determines if the modem sends information regarding status (Call
Progress) and/or sends summarized call statistics (Call Connect) to the
dial network management system (COMSPHERE 6700 Series NMS).
Register has the following values:
0=Call Connect & Progress
1=Disable
2=Call Connect Only
3=Call Progress Only
The factory default templates do not affect S66.
S67
Directory Location 1 Callback
Register determines if the modem uses the single number callback
function.
Register has the following values:
0=Disable
1=Enable
Factory setting is Disable.
S69
Make Busy Via DTR
Register determines if the modem goes off-hook (busy) when DTR is Off.
Register has the following values:
0=Disable
1=Enable
Factory setting is Disable.
13-28
Table 13-2
(11 of 15)
3800 Plus S-Registers
Description
October 1998
Front Panel Branch
Configure\Edit\
DTE Dialer
Configure\Edit\
DTE Dialer
Configure\Edit\
DTE Dialer
Configure\Edit\Misc
Configure\Edit\Misc
Configure\Edit\
Line Dialer