Technical Data; Metpoint ® Ocv Sensor Unit - Beko METPOINT OCV Installation And Operation Manual

Oil vapour measuring device with sampling probe
Table of Contents

Advertisement

Technical data

6
Technical data
®
6.1
METPOINT
OCV sensor unit
Measuring medium:
Measurand:
Identifiable substances:
Ambient temperature:
Compressed-air
temperature at the inlet:
Operating overpressure:
Measuring gas humidity:
Measuring range:
Measuring accuracy:
Detection limit (residual
oil):
Amount of measuring
gas:
Fields of application:
Dimensions:
Weight:
Power supply:
Max. operating current:
Power consumption:
External fusing:
Power cord:
Protection class:
Connection probe:
Probe type 1:
Probe type 2:
Probe type 3 :
12
Compressed-air free from aggressive, corrosive, caustic, toxic, flammable and fire-
accelerating constituents
Residual oil content in mg oil / standard m³ (based on 1.0 bar, +20°C, 0% relative humidity)
in accordance with ISO 8573-1
Polyalphaolefins, aromatics
Aliphatic hydrocarbons
Hydrocarbons
Functional hydrocarbons
+5°C to +45°C
+5°C to +55°C
3 bar(g) to max. 16 bar(g) --> see type plate (cf. also page 3)
≤ 40 % rel. humidity, pressure dew point max. +10°C, non-condensable humidity
≤ 0.01 – 5.000 mg/m³ residual oil content (in accordance with ISO 8573-1)
The measuring accuracy is 0.003 mg/m³.
0.0006 mg/m³
Approx. 2 to 3 standard litres/minute related to 1.0 bar absolute and +20°C (expanded)
The amount of measuring gas depends on the operating pressure.
NOTE!
The measuring gas is released into the environment. Please consider the resulting
concentration values at the place of installation of the METPOINT
ventilation.
Downstream of an activated-carbon filter (see installation instructions Chapter 10.5)
Downstream of an activated-carbon adsorber
Downstream of a BEKOKAT (catalytic converter)
Downstream of an oil-free compressor
Each with corresponding upstream filtration and drying
487 x 170 x 120 mm (W x H x D)
Approx. 6.6 kg
Version 1: 230 V AC 50 Hz +/- 10%
Version 2: 115 V AC 60 Hz +/- 10%
0.3 A at 230 VAC
41 W
2.0 A, slow, recommended
Max. cladding diameter: 6.5 mm, strand cross section: 0.75 mm²,
with safety plug and PE protective earthing
Standard IP 20
G 3/8" internal thread
DN 20 to DN 40
DN 50 to DN 80
> DN 80
¾" to 1 ½"
2" to 3"
produced in accordance with the customer's
requirements
®