Installation Diagram Metpoint ® Ocv With Bekokat - Beko METPOINT OCV Installation And Operation Manual

Oil vapour measuring device with sampling probe
Table of Contents

Advertisement

10.3 Installation diagram METPOINT
1
Compressor (oil-lubricated)
2
Cyclone separator with BEKOMAT
3
Universal filter (G) with BEKOMAT (OPTIONAL at strongly contaminated compressed air)
4
Compressed-air tank
5
BEKOMAT for the tank drainage
6
BEKOKAT
7
Dust filter (F) with BEKOMAT
8
Minimum requirement: refrigeration dryer
9
Super-fine filter (S) with BEKOMAT
10
Sensor unit METPOINT
11
Evaluation unit with user interface (display) METPOINT
H1/H2
Shut-off valves of the measuring section
H3
Shut-off valve of the bypass
H4
Vent valve of the measuring section
The depicted installation shows the minimum requirement of the METPOINT
Other types of installation are possible (provided that they meet the defined operating conditions).
For service measures, it is recommended to install a bypass at the METPOINT
components to be serviced in compressed-air systems.
Please observe that this bypass must also be free from oil and grease!
CAUTION!
Contaminated input air – inferior operating conditions!
When employing the METPOINT
damaged or destroyed!
METPOINT
®
OCV
®
OCV with BEKOKAT
®
OCV
®
OCV under inferior operating conditions, the device can be contaminated,
Oil-and grease-free zone
®
OCV
®
OCV in combination with a BEKOKAT.
®
OCV. This applies generally to all
Installation