Panasonic KX-TD500 Features Manual page 130

Digital super hybrid system
Hide thumbs Also See for KX-TD500:
Table of Contents

Advertisement

General Features
c)
The DISA OGM(s) should be recorded by the Manager or an Operator.
d)
The OGM Type should be set to "DISA" under OGM Group setting.
• DISA Delayed Answer Time
A DISA call is answered after a ringback tone is returned to the caller after the "DISA
Delayed Answer Time" expires. The caller can dial while hearing the OGM message.
• DISA User Code
This system can store up to 32 programmable DISA user codes with a COS (Class of
Service) level for each. Each code should be unique.
• DISA User Code Entry Failure
If the DISA caller fails to enter the valid DISA user code three times consecutively, the call
will be disconnected.
• DISA built-in Automated Attendant Table
This system can store up to 8 DISA built-in auto attendant number tables, each having 10
one-digit numbers.
• DISA built-in Automated Attendant Number
The DISA built-in auto attendant number may be the same as the first digit of other numbers
(extension number, Floating Number, etc.). To avoid confusion, the system waits for the
second digit for a pre-programmed amount of time (default: 1 second). If the second digit
is not dialed before the timer expires, the system assumes that the first digit is a DISA built-
in auto attendant number.
• Call Forwarding - to CO or TIE Line
When a DISA call is forwarded to an outside party, the caller is not required to enter a DISA
user code regardless of the Security modes.
• CO-to-CO line call duration
The duration of CO-to-CO line calls can be limited by System Programming. When a
specified period of time (default:10 min) expires, both lines are disconnected unless the
caller prolongs the duration time, if available. A warning tone is sent to both parties 15
seconds before the time limit at 5-second intervals.
• Prolonging the duration of CO-to-CO line call is possible. To prolong the call duration, the
caller should press any dialpad key except . The amount of prolonging is set by "DISA
Prolong Time" (0 to 7 minutes). (If this is set to zero, then prolonging is disabled.)
Depending on System Programming <Section 2.8 System Option, "13. DISA prolong
operation" in the Programming Guide>, the call duration can be prolonged 10 times or
without limit.
• To detect the end of a CO-to-CO line call, CPC Signal Detection and Tone Detection can
be assigned.
• Tone Detection
The following three ways of "Tone Detection" are provided <Section "3.2 Trunk Group" in
the Programming Guide> to disconnect a CO-to-CO line call.
1. Cyclic Signal Detection:
Used to disconnect the trunk line when the system detects a cyclic signal during a CO-
to-CO line call by DISA or AGC.
2. Continuous Signal Detection:
Used to disconnect the trunk line when the system detects a continuous signal during a
CO-to-CO line call by DISA or AGC.
130