Panasonic CPC-EX Installation Manual page 77

Digital business system section 300 (applies to cpc-aii/b version 9.2 and cpc-ex version 2.3)
Table of Contents

Advertisement

Section 300-Installation
Installing T1 in a Double Cabinet with T1s in the Master and Slave
1. Install the Sync Unit in the master cabinet as described in Steps 1 and 2
2. Install a T1 MDF card in each cabinet. (See Step 3 on page 4-23.)
3. Set Switch 1 on the T1 cards. (See Step 4 on page 4-24.)
4. Install a T1 card in each "EC/TRK" slot.
5. Connect the Clock Sync Cable from CN4 on the master-cabinet T1 to
6. At the master cabinet, connect the Sync Cable from CN1 on the Sync
7. At each cabinet, connect the cable attached to CN3 on the T1 MDF card
8. Using an RJ48 cable, connect CN1 of each T1 MDF card to a CSU. (See
9. For both cabinets, connect the ground cable from the T1 MDF card as
DBS-2.3/9.2-300
under "Installation for a Single T1."
CN5 on the slave-cabinet T1, as shown in Figure 4-12.
Note: Part Number VB-43564 is used for the Clock Sync Cable when
T1s are installed in the master and slave cabinets.
Unit to CN5 on the T1 card (Figure 4-12).
to CN3 on the T1 card (Figure 4-10).
Figure 4-9 on page 4-25 for RJ48 pinouts.)
shown in Figure 4-10 on page 4-26.
DBS Manual - Revised April 2000
Chapter 4. Trunks and Lines
4-29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vb-43030Vb-43050Vb-43060Dbs 40Dbs 72Dbs 96