Chapter 5. Peripheral Equipment
Requirements
• Trunks used for Door Boxes and openers must be set up as dial pulse
• Equipment combinations used with the Door Box Adaptor require the
• The following tools are required to install the Door Box Adaptor:
Installation
1. Remove the cover from the Door Box Adaptor.
2. Set the switches in the Door Box Adaptor as shown in Figure 5-16.
3. Remove the cable punch-out plate Figure 5-12 in order to make an
5-28
trunks.
number of trunks in the following table:
If you use . . .
1 sensor and 1 Door Box/opener
1 sensor and 2 Door Boxes/open-
ers
1 sensor
1 Door Box/opener
- Phillips screwdriver
- Needle-nose pliers
- Diagonal shears.
opening for the cables coming into the Door Box Adaptor.
To remove the plate, cut the grooves on either side with diagonal shears.
Then bend the plate back and forth with needle-nose pliers to remove it.
DBS Manual - Revised April 2000
Section 300-Installation
The adaptor uses
2 trunks
2 trunks
1 trunk
1 trunk
DBS-2.3/9.2-300