Table 2-3. Printed Circuit Package Slot Usage - Panasonic CPC-EX Installation Manual

Digital business system section 300 (applies to cpc-aii/b version 9.2 and cpc-ex version 2.3)
Table of Contents

Advertisement

Chapter 2. System Overview
Printed circuit cards are installed in dedicated slots in the DBS cabinet.
Table 2-3 shows the cards that can be installed in each slot. Figure 2-3 on
page 2-9 illustrates slot labels.

Table 2-3. Printed circuit package slot usage

Card Type
Analog
Trunks
Digital Trunks
Digital Lines
Analog Lines
Service
Circuits
Processor Cards
DTMF Circuits
Interface Cards
Notes:
1. With one-cabinet systems, the MFR card can be installed in the AUX1 or AUX2 slot,
depending on whether an API card is used. With two-cabinet systems, placement of the MFR
cards differs according to the cable kit used. With Cable Kit Version 1.1, one MFR is installed
in the Master AUX1, and one MFR is installed in the Slave AUX1. With Cable Kit Version
1.2, both MFR cards are installed in the slave cabinet--one in the CPC slot and one in AUX1.
(See page 6-10 for instructions on installing MFR cards in double-cabinet systems.)
2. The API card is installed in AUX1 only when a CBL card is used.
3. Part VB-43110 includes both the CBL-M and CBL-S cards, as well as the required connect-
ing cables. CBL-M is installed in the master cabinet, CBL-S in the slave cabinet.
2-8
Card
L-TRK/4
L-TRK/8
G-TRK/8
DID/8
T1/24
DEC/8
AEC/8
SCC-A
SCC-B
CPC-A
CPC-B
CPC-AII
MFR/8
API (1 or 2 Circuits)
CBL-M
CBL-S
DBS Manual - Revised April 2000
Section 300-Installation
Acceptable Slots
TRK or EC/TRK
EC/TRK
EC 1-8 or EC/TRK
EC 2-8 or EC/TRK
SCC
CPC
AUX1 or AUX2
CPC (See Note 1.)
AUX1 or AUX2 (See Note 2.)
CPC or AUX2 (See Note 3.)
DBS-2.3/9.2-300

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vb-43030Vb-43050Vb-43060Dbs 40Dbs 72Dbs 96