Off-Premises Adaptor (Opx); Guidelines - Panasonic CPC-EX Installation Manual

Digital business system section 300 (applies to cpc-aii/b version 9.2 and cpc-ex version 2.3)
Table of Contents

Advertisement

Chapter 5. Peripheral Equipment

Off-Premises Adaptor (OPX)

Guidelines

• Analog phones can be connected as off-premise stations through a direct
Table 5-4.
Maximum distances for direct connection to OPX stations
Wiring
gauge
AWG 22
AWG 24
AWG 26
• One OPX Adaptor (VB-43702) is required for each OPX station.
• The ringing output of the OPX Adaptor is 225 Vp-p (peak-to-peak) at 20
• When OPX stations are connected through the central office, an external
• Order an OL13C circuits for OPX stations connected through a CO.
• The following tools are required to install the OPX Adaptor:
5-10
line to the DBS or through the central office, depending on how far the
stations are from the OPX Adaptor.
Table 5-4 shows how far the OPX stations can be from the adaptor without
going through a CO.
Max. distance (in feet) between
the OPX Adaptor and the OPX
station
27877
17532
11025
Hz.
ringer supply may be required. If required, the ringing supply is connected
to the OPX Adaptor.
- Phillips screwdriver
- Needle-nose pliers
- Diagonal shears.
DBS Manual - Revised April 2000
Section 300-Installation
DBS-2.3/9.2-300

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vb-43030Vb-43050Vb-43060Dbs 40Dbs 72Dbs 96

Table of Contents