Panasonic CPC-EX Installation Manual page 129

Digital business system section 300 (applies to cpc-aii/b version 9.2 and cpc-ex version 2.3)
Table of Contents

Advertisement

Section 300-Installation
Table 5-11. Maximum distances for SLTA installation
Wiring
Max. distance (in feet) between
gauge
the DBS and SLTA
AWG 22
300' or 10 W
AWG 24
190' or 10 W
AWG 26
120' or 10 W
4. If the DBS is powered up, turn off the power.
5. Connect the GND and +24V leads on the SLTA to the DBS connector
6. Turn on the DBS power.
7. Connect the "T" and "R" leads to the digital extension ports on the DBS
8. Connect the SLT "T" and "R" leads to the SLTs.
9. Install the cover on the SLTA.
DBS-2.3/9.2-300
panel. Be sure the wires do not touch each other or touch the metal
frame housing.
as per Figure 5-21. One digital extension port is required for each SLT.
DBS Manual - Revised April 2000
Chapter 5. Peripheral Equipment
Max. distance (in feet) between
the SLTA and the SLT
3000' or 100 W
1900' or 100 W
1200' or 100 W
5-35