PR 5331A Manual page 16

2-wire programmable transmitter
Table of Contents

Advertisement

LERBAKKEN 10, 8410 RØNDE DENMARK.
For safe installation of 5331D or 5334B the following must be observed. The module shall only be
installed by qualified personnel who are familiar with the national and international laws, directives
and standards that apply to this area.
Year of manufacture can be taken from the first two digits in the serial number.
ATEX Certificate
Marking
Standards
Hazardous area
Zone 0, 1, 2, 20, 21, 22
T4: -40 ≤ Ta ≤ 85ºC
T6: -40 ≤ Ta ≤ 60ºC
Terminal: 3,4,5,6
Uo: 9.6 VDC
Io: 25 mA
Po: 60 mW
Lo: 33 mH
Co: 2.4μF
Revision date:
2013-08-07
14
ATEX Installation drawing
KEMA 06ATEX 0062 X
II 1 G Ex ia IIC T4...T6 Ga
II 1 D Ex ia IIIC Da
II 1 M Ex ia I Ma
EN 60079-0 : 2012, EN 60079-11 : 2012, EN 60079-26 : 2007,
EN 60079-15 :2010
6
5
4
5331D
3
5334B
Terminal: 1,2
Ui: 30 VDC
Ii: 120 mA
Pi: 0.84 W
Li: 10 μH
Ci: 1.0 nF
Version Revision
V2R0
5331V11 4 -UK
WWW.PRELECTRONICS.COM
Non Hazardous Area
+
1
-
2
Barrier
5331QA01
Page: