PR 5331A Manual page 15

2-wire programmable transmitter
Table of Contents

Advertisement

LERBAKKEN 10, 8410 RØNDE DENMARK.
For safe installation of 5331A3B or 5334A3B the following must be observed. The module shall
only be installed by qualified personnel who are familiar with the national and international laws,
directives and standards that apply to this area.
Year of manufacture can be taken from the first two digits in the serial number.
ATEX Certificate
Marking
Standards
T4: -40 ≤ Ta ≤ 85ºC
T6: -40 ≤ Ta ≤ 60ºC
Special conditions for safe use.
For type of protection Ex nA, the transmitter shall be mounted in a metal enclosure providing a
degree of protection of at least IP54 according to EN60529.
For use in the presence of combustible dusts the transmitter shall be mounted in an enclosure
providing a degree of protection of at least IP6X in accordance with EN60529, the surface
temperature of the outer enclosure is 20 K above the ambient temperature.
For an ambient temperature ≥ 60ºC, heat resistant cables shall be used with a rating of at least
20 K above the ambient temperature.
Revision date:
2013-08-07
ATEX Installation drawing
KEMA 10ATEX 0002 X
II 3 G Ex nA [ic] IIC T4 ... T6 Gc
II 3 G Ex ic IIC T4...T6 Gc
II 3 D Ex ic IIIC Dc
EN 60079-0 : 2012, EN 60079-11 : 2012, EN 60079-15 : 2010
Terminal: 3,4,5,6
Ex nA [ic]
Uo: 9.6 V
Io: 25 mA
Po: 60 mW
Lo: 33 mH
Co: 2.4 μF
Version Revision
V2R0
5 33 1 V 1 14 - UK
WWW.PRELECTRONICS.COM
Terminal: 1,2
Terminal: 1,2
Ex nA
Ex ic
Umax ≤ 35 VDC
Ui = 35 VDC
Ii = 110 mA
Li = 10 μH
Ci = 1.0 nF
5331QA02
Page:
1/1
13