Rectifying Malfunctions
Malfunction: Cordless pruning shears do not run after switch-on
Message after diagnosis
Check component
Testing the Battery
BATT KO
Check connection between battery and bat-
tery bag
BATT KO
Check connection between battery bag and
control unit
POWERLINE KO
Check connection between control unit and
pruning shears
TRIGGERLINE KO
Check connection between control unit and
pruning shears
ASA 85
Cause
Insufficient state of charge
(1 LED on battery flashes green)
Battery too hot / too cold
(1 LED on battery glows red)
Malfunction
(4 LEDs on battery flash red)
Moisture in power tool's electronics or
battery
No electrical contact
No electrical contact
No electrical contact
No electrical contact
Remedy
Charging the Battery
Allow battery to cool down / allow battery
to warm up slowly at temperatures of
about 15°C - 20°C (60°F - 70°F)
Remove the battery and refit it
Allow power tool electronics or battery to
dry
Remove the battery, visually check con-
tacts. Use a blunt tool to carefully clean
the contacts in the battery bag. Refit the
battery. Close the quick release buckle
on the battery bag and tighten the strap.
Check connection. Remove plug from
control unit and refit.
Check connection. Tighten down the
union nut firmly by hand.
Check connection. Tighten down the
union nut firmly by hand.