Position the grease gun on the
N
grease nipple and pump grease into
the reservoir. One or two strokes
are sufficient.
2
Lubricate seat of pivot pin (2) with
N
grease.
Fit the pivot pin (2).
N
Fit a new E-clip (supplied with
N
power tool) on the pivot pin (2).
Replacing the Anvil Blade
The anvil blade must be replaced:
when the cutting blade has been
–
replaced several times
if a clean cut cannot be obtained
–
even though the play between the
cutting and anvil blades is correct
Removing the anvil blade
Remove the cutting blade – see
N
"Replacing the Cutting Blade".
ASA 85
1
Take out the screws (1) and remove
N
the anvil blade (2).
Clean the anvil blade.
N
Fitting the new anvil blade
Fit the new anvil blade (2) in
N
position.
Insert the screws (1) and tight them
N
down to a torque of 7 Nm.
Fit the cutting blade – see
N
"Replacing the Cutting Blade".
Opening and Closing the Cutting Blade
Manually
If required, the cutting blade and can be
opened or closed by rotating the motor
by hand.
Engage screwdriver in slotted screw
N
in center of bushing.
Rotate clockwise:
Rotate
counterclockwise
2
English
Cutting blade
opens
Cutting blade
closes
23