Auxiliary Hydraulics; Joystick Valve; Remove Valve Type - Kioti CK20 Owner's Manual

Hide thumbs Also See for CK20:
Table of Contents

Advertisement

AUXILIARY HYDRAULICS

JOYSTICK VALVE

(T) To the Tank
(P) From the Pump
(A1) A1 Port
(A2) A2 Port
(B1) B1 Port
(B2) B2 Port
Boom Cylinder : A1,B1
Bucket Cylinder : A2,B2
NOTE
When the lever is at each corner po-
sition marked by*, boom and bucket
cylinders work at the same time.
However, the position marked by
cross is not recommended for scoop-
ing because of insufficient lift force.
196O906A
To begin test operation, slightly move the
control lever from the "N" position. Slowly
raise the loader boom just enough for the
bucket to clear the ground when fully
dumped. Slowly work through the dump
and roll back cycles.
IMPORTANT
If the boom or bucket does not
work in the directions indicated
in the label, lower the bucket to
the ground, stop the engine, and
relieve all hydraulic pressure. Re-
check and correct all hydraulic
connections.

REMOVE VALVE TYPE

This loader control valve has two stage
dump position. The first dump position by
moving the lever to the right is the "Regu-
lar" dump position.
It has good power and control for dump-
ing precisely. This position should be
used when operating another implement
with the loader's control valve.
The second dump position (to further
right) features greater speed for
dumping. These two position are sepa-
196O907A
rated by a "Feel " position for your
convenience.
IMPORTANT
Do not move the control lever
into float position when the
bucket is off the ground.
HYDRAULIC UNIT 9-5