3
. LUBRICATION SYSTEM
DISASSEMBLY
Remove the three oil pump mounting bolts
and the oil pump body.
INSPECTION
Measure the pump body-to-outer rotor
clearance.
Service Limit: 0.20mm
Measure the inner rotor-to-outer rotor
clearance.
Service Limit: 0.20mm
Measure the rotor end-to-pump body
clearance.
Service Limit: 0.15mm
3-5
Bolts
Outer Rotor
Outer Rotor
VENOX
250
Feeler Gauge
Pump Body
Feeler Gauge
Inner Rotor