Chapter 6
c. Ensure the ridge on the bottom of the heatsink rest between the processor and the edge of
the processor socket base.
CAUTION
4. Connect the heatsink's cooling fan cable to the 2nd cooling fan connector (CPU 2 Fan) on the
system board.
CAUTION
5. Replace the cooling duct/cover and the NetServer cover.
6. Fasten the six thumbscrews securing the cover to the chassis.
7. Replace the external cables and power cord.
8. Power up the NetServer as described in Chapter 1.
86
Hook Latch
(hidden)
Step A
Tab
Step C
Ensure you have made good contact with the processor to avoid thermal
overheating. If you have not made good contact with the processor, it will overheat
within 20 seconds of power on and will shut down, possibly causing damage to the
processor.
Failure to connect the cooling fan to its power connector will cause the NetServer to
shut down with no messages displayed and possible damage the processor.
Thumb
Latch
Tab
Processor
Socket
Base
Replacing Parts