Vega VEGAPULS 63 Operating Instructions Manual page 15

Radar sensor for continuous level measurement of aggressive liquids or with hygienic requirements
Hide thumbs Also See for VEGAPULS 63:
Table of Contents

Advertisement

Sensor orientation
Vessel installations
VEGAPULS 63 • Profibus PA
Fig. 8: Deviating socket dimensions
In liquids, direct the sensor as perpendicular as possible to the prod-
uct surface to an achieve optimum measurement.
Fig. 9: Alignment in liquids
The mounting location of the radar sensor should be a place where no
other equipment or fixtures cross the path of the microwave signals.
Vessel installations such as for example, ladders, limit switches, heat-
ing spirals, struts etc. can cause false echoes that interfere with the
useful echo. Make sure when planning your measuring site that the
radar signals have a "clear view" to the measured product.
In case of existing vessel installations, a false echo storage should be
carried out during setup.
If large vessel installations such as struts or supports cause false
echoes, these can be attenuated through supplementary measures.
Small, inclined sheet metal baffles above the installations scatter the
radar signals and prevent direct interfering reflections.
Fig. 10: Cover flat, large-area profiles with deflectors
d
4 Mounting
15