The following table sums up which parameters can be set and the related range settings.
MENU
PARAMETER
CH
GR
TUNING
Freq
AF In Gain
AF Level
Phase
AUDIO
HP Filt.
Noise R.
RF Power
RF/BATTERY
Battery
Led Light
LED
Led Mode
Mode
MIC
PTT Mode
MEANING
RANGE SETTINGS
Channel
0 ÷ 59
Group
0 ÷ 39 + SYNC GROUP
depends on the MTP41 Model:
Frequency
Gain of the
-60dB ÷ +40dB step of 1dB
audio signal
-54dBu ÷ +46dBu step of 1dBu
Audio signal
0° or 180°
phase
High Pass filter
Flat/60/80/120/170/250/400 Hz
ENR: Wisycom Extended-NR, noise optimized
Noise reduction
ENC: Wisycom Extended-NC, voice optimized
50mW / 10mW (depending on the power
RF Power
profile)
Battery type
Alkaline / NiMH / Lithium
Power switch
green
0 ÷ 16
brightness
It defines when
the power
None: never
switch led (see
ModPeak: when audio get close to saturation
Fig. 3) has to
PTT: when the PTT button is pushed
become RED
'2 wires'
MIC type
'2 wires + bias'
'3 wires'
Disable: when the PTT button is pushed, nothing
happen. (the transmitter sends AF+Tone
squelch).
Normal: when the PTT button is pushed, the
It defines how
transmitter send a different RF signal. According
and what
to the receiver configuration the audio can be
information the
enabled/disable on LINE (and/or COM).
transmitter has
Muting: the transmitter doesn't send the audio.
to send
The voice is cut, it doesn't enter to the
microphone.
No Data: the transmitter sends neither tone
squelch nor battery data.
MTP41 User Manual
1
470-640
2
566-798
3
510-698
11