FOR INSTALLATION AND USE IN OUTDOOR OR AMPLY VENTILATED AREAS
•
An amply ventilated area must have a minimum of 25%
of the surface area open.
•
The surface area is the sum of the walls surface
An amply ventilated area must have a minimum of 25% of
the surface area open. The surface area is the sum of the
walls surface.
"The tubing or the flexible hose must be changed within the
prescribed intervals";
"Use only the type of gas and the type of cylinder specified
by the manufacturer";
This
appliance
must
gas cylinder stored in accordance with the
regulations in force.
!
IMPORTANT
This appliance shall only be used in above ground open-air
situations with:
•
natural ventilation
•
without stagnant areas
•
where gas leakage and products of combustion are
rapidly dispersed by wind and natural convection
Any enclosure in which the appliance is used shall comply
with one of the following:
1.
25% of surface area is open. The surface area is the sum
of the wall surface (ref. Appendix A, Example 1)
2.
Within a partial enclosure that includes an overhead
cover and no more than two walls
Example 2)
3.
Within a partial enclosure that includes an overhead
cover and more than two walls, the following shall apply:
•
At least 25% of the total wall area is completely open
(ref. Appendix A, Example 4), and
•
At least 30% of the remaining wall area is open and
unrestricted (ref. Appendix A, Example 4)
Note: The definition of outdoors is an above ground open-
air situation with natural ventilation, without stagnant areas,
where gas leakage and products of combustion are rapidly
dispersed by wind and natural convection.
be
installed
and
(ref. Appendix A,
www.bromicheating.com
GAS REQUIREMENTS
Tungsten Smart-Heat LPG Models:
•
Use Propane (LPG) gas only
•
The approved inlet pressure to the appliance
Tungsten Smart-Heat Natural Gas Models:
•
Use Natural Gas Only
•
The approved inlet pressure to the appliance