Bromic Heating STRATOS BRAHMA 3.0 NG Installation, Instruction And  Service Manual

Bromic Heating STRATOS BRAHMA 3.0 NG Installation, Instruction And Service Manual

Flued indoor gas heater

Advertisement

BROMIC FLUED INDOOR GAS HEATER
BROMIC FLUED INDOOR GAS HEATER
STRATOS 3.0 / 5.0 / 7.0 / 9.0
BROMIC BRAHMA STRATOS 3.0 / 5.0 / 7.0 / 9.0
INSTALLATION, INSTRUCTION AND
INSTALLATION, INSTRUCTION
SERVICE MANUAL
AND SERVICE MANUAL
BROMIC.COM/PLUMBING
1300 276 642
A member of the Bromic Group
PRODUCT IMAGE
August 2019-v1.1
July 2019 - V1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STRATOS BRAHMA 3.0 NG and is the answer not in the manual?

Questions and answers

Summary of Contents for Bromic Heating STRATOS BRAHMA 3.0 NG

  • Page 1 BROMIC FLUED INDOOR GAS HEATER BROMIC FLUED INDOOR GAS HEATER STRATOS 3.0 / 5.0 / 7.0 / 9.0 BROMIC BRAHMA STRATOS 3.0 / 5.0 / 7.0 / 9.0 INSTALLATION, INSTRUCTION AND INSTALLATION, INSTRUCTION SERVICE MANUAL AND SERVICE MANUAL PRODUCT IMAGE BROMIC.COM/PLUMBING 1300 276 642 A member of the Bromic Group...
  • Page 2 CODE MODEL MODEL CODE CODE MODEL CODE MODEL CODE STRATOS BRAHMA 3.0 NG 2620970 BRAHMA STRATOS 3.0 NG BRAHMA STRATOS 3.0 NG 2620970 2620970 3 . 0 3 . 0 a l u m i n u m a l u m i n u m...
  • Page 3 INDEX INDEX GENERAL GENERAL GENERAL General informations General informations General informations pag.5 pag.5 Safety rules Safety rules Safety rules pag.5 pag.5 Appliance description Appliance description pag.6 pag.6 Appliance description Identification Identification pag.6 pag.6 Structure Structure pag.7 pag.7 Identification Technical data Technical data pag.8 pag.8...
  • Page 4: General Informations

    GENERAL INFORMATIONS After removing the packaging, check the integrity of This booklet is an integral part of the appliance and the contents. In case of discrepancies, contact the must therefore be carefully looked after and Agency that sold the appliance. ALWAYS accompany the APPLIANCE, including when this is sold to another user or transferred to The APPLIANCE must be used as intended by the...
  • Page 5: Appliance Description

    APPLIANCE DESCRIPTION The appliance is a gas radiator that heat up the Note: At request the apparatus can be furnished atmosphere. already arranged at GPL. It has an intake of air that goes in the combustion chamber type C. It also has an electrical device that allows you to do a series of things.
  • Page 6 STRUCTURE                                        ...
  • Page 7: Technical Data

    TECHNICAL DATA MODEL Natural Propane Natural Propane Natural Propane Natural Propane Terminal capacity nomination (qn) (Hi) 10,5 10,5 18,5 18,5 27,5 26,0 32,0 33,0 Mj/h Terminal capacity reduction (qn) (Hi) 13,4 13,1 19,7 18,8 20,9 21,1 Mj/h Terminal power convector nomination (pn) (Hi) 2,45 2,45 4,24...
  • Page 8 July 2019 - V1...
  • Page 9: Control Panel

    CONTROL PANEL - On/Off key and device RESET - Reduce temperature key (MIN 5°C) - Light display - Increase temperature key (MAX 35°C) - Enable/disable Wireless command key DESCRIPTION OF DISPLAY DESCRIPTION OF ICONS This type of screen simultaneously provides an 1 - operation at MAX power.
  • Page 10: Receipt Of Product

    RECEIPT OF PRODUCT The appliance is supplied in one cardboard package: Contents of appliance package: Appliance Manual control Metal template Pipe KIT: 1 Adapter union 1 Suction pipe (L = 500mm) (Ø 32mm Mod. 3.0 - 5.0) (Ø 54mm Mod. 7.0 - 9.0) 1 exhaust pipe (L = 500mm) (Ø...
  • Page 11 WEIGHT & DIMENSION                                      ...
  • Page 12 INSTALLATION: WALL FITTING or FLOOR STANDING GENERAL INFORMATIONS This apparatus is tin respect to the environment; the air is intake from the outside. -When the appliance is being installed do not use other pieces that are not give from the manufacturer. -Don’t let the electrical cable touch heated parts, like the grill or the intake &...
  • Page 13 INTAKE AND EXHAUST TUBE FUMES ASSEM- BLAGE The intake & exhaust tubes can be embedded insi- de the wall, or in sight, they have to be protected to avoid, risk condition. To have the apparatus in sight it exist a spacing bar so that you can see the tubes, we recommend that the exhaust tubes have to have a good insulation using materials that have also a resistant of more 200°...
  • Page 14 FITTING THE TEMPLATE, UNION AND PIPES To determine the position of the APPLIANCE and of the support template (3), use the paper template (4) provided: - level and mark the holes (1, 2), then remove the paper template from the wall; - make the holes (2) for fastening the template to the wall;...
  • Page 15 Outside grill assemblage GP and GPu Ø32 To assemble the grill you only need the inserts, and the steeliness steel flange. Ø54 Assemblage SDP protection Ø32 The assembling is execute in the following way: -After you have drilled on the outside wall put the protection (1) with mortar -Assemblage the terminal tube with the equipment Ø54...
  • Page 16 July 2019 - V1...
  • Page 17: Floor Standing

    FLOOR STANDING MOUNTING THE “FLOOR STANDING” SUPPORT STRUCTURE IMPORTANT! Read and respect the general information of INSTALLATION chap. The support structure kit is used when the wall selec- ted for installation is unable to support the weight of the appliance. Thanks to this accessory, all the wei- ght of the appliance is discharged onto the floor.
  • Page 18 PROTECTION FOR WALLS MADE OF WOOD PANELS FITTING SILUMINA FRAME ASSEMBLY FOR INSTALLATION ON COMBUSTIBLE OR WOODEN WALL This assembly is suitable for walls between 100 mm 2) Fit the external stainless - stell (3) AISI 304 to the and 500 mm thick. outside of the wall using the 4 screws, included in the pack, if the external wall is hard stone chose - Having chosen the position for the heater in accor-...
  • Page 19: Power Connections

    POWER CONNECTIONS This apparatus is equipped with a cable with plug for connection to the mains power supply. A proper earth connection is mandatory. The manufacturer of the appliance cannot be held liable for any damage caused by lack of proper earth connection.
  • Page 20: Preliminary Operations

    PRELIMINARY OPERATIONS Only fill the tray with water. Avoid all other The appliance is furnished and preset for the gas liquids that could damage the tray or cause function (G 20) and regulated in factory. appliance malfunctions. Note: the apparatus can also be requested with the GPL gas function.
  • Page 21 PROCESSOR CONTROL BOX (P.C.B ASSY) MALFUNCTION In case of any malfunctions in the control unit, RESET as follows: a - press the On/Off button as shown in the illustra- tion. b - connect and disconnect the plug from the socket or move the master switch to “off”...
  • Page 22: Gas Transformation

    GAS TRANSFORMATION The appliance is preset for the methane gas (G20) following the technical label, but you can  change at GPL (G30/G31) with the transformation that is furnished. The transformation has to be done only by Technical Service Assistance, the manufacturer or by authori- zed persons even if appliance has been already installed.
  • Page 23 REGOLATION The appliance is furnished with (G20) gas function following the Technical label, and the constructor already regulates it. If you make a new regulation, like exchanging the gas valve, or a gas transforma- tion from Methane to GPL or reversed, this regula- tion has to be done from a Technical service Assistance or by the manufacture Gas methane G 20(20mbr);...
  • Page 24: Ordinary Maintenance

    Whenever the apparatus is going to be regulated at the modulator body (4). pure Propane, to avoid heat exchanger overheating, Rotating the regulator screw (3) clockwise the pres- is necessary knowing that you are using the proper sure decrease, rotating counter clockwise the pres- gas, but if you use a un proper gas like a mixture of sure increases.
  • Page 25: Components Replacement

    Cleaning Electrode The ignition electrode (1) and revelation (2) have to be cleaned very carefully, after a period of time they get fragile because of the work they have to perform. - Unscrew the screws (3 o 4) and extract the electro- de group (1 o 2) using a little brush with metallic hair for cleaning, after insert the electrode group (1 o 2) if necessary exchange the seal gasket (5) be real...
  • Page 26 Replacing the room probe  Follow the instructions below to remove and refit the probe: - disconnect the connector of the probe cable (1) from the control unit (2); - take out the damaged probe; - replace the component part and fit it back, perfor- ming removal operations in the opposite sequence.
  • Page 27 Electrodes replacement   Follow the indication to replace the electrode. - The ignition electrode (1) and revelation (2) half to be cleaned real carefully, after a period of time they get fragile because of the work they which they do. ...
  • Page 28 Replacing the gas valve Follow the instructions below to remove and refit the valve:  - remove the power connections. - loosen the retention nut that secures the burner pipe (1) to the valve body (2).  - loosen the retention nut that secures the mains gas pipe (3) to the valve body.
  • Page 29 DISASSEMBLY & RIASSEMBLY OF THE CASING Disassembly cover  - Disassembly the casing;  - Remove the cup (3); - Unscrew the screw (2); - Remove the outside skirt (1) completely; - To replace the skirt do the reversed sequence. ...
  • Page 30 FAULT CAUSE REMEDY The thermostat does not engage. Thermostat programming wrong Adjust thermostat: - increase - decrease. Unfavourable appliance position. Change appliance position PROBE offset faulty. Offset correctly Upper or lower grille blocked Clean / Free SPLIT probe has come out of seat. Position correctly INTEGRATED room probe faulty Replace Probe or Wireless...
  • Page 31: Useful Information

    USEFUL INFORMATION Seller Street tel. Installer Street tel. Technical Service Assistance Street tel. Date Intervention July 2019 - V1 CUSTOMER SERVICE...
  • Page 32 NOTE July 2019 - V1 NOTE...

Table of Contents