Lenovo 3000 K100 Hardware Maintenance Manual page 51

Hide thumbs Also See for 3000 K100:
Table of Contents

Advertisement

Diagnostic Error Code
089-199-XXX
Microprocessor test failed, cause
unknown
170-000-XXX
Voltage Sensor(s) Test Passed
170-0XX-XXX
Voltage Sensor(s) failure
170-195-XXX
Voltage Sensor(s) Test aborted by
user
170-196-XXX
Voltage Sensor(s) test halt, error
threshold exceeded
170-197-XXX
Voltage Sensor(s) test warning
170-198-XXX
Voltage Sensor(s) test aborted
170-199-XXX
Voltage Sensor(s) test failed, cause
unknown
170-250-XXX
170-251-XXX
Voltage Sensor(s) Voltage limit error
170-254-XXX
Voltage Sensor(s) Voltage Regulator
Module error
Chapter 6. Symptom-to-FRU Index
FRU/Action
1. See
"Undetermined problems"
2. Flash the system and re-test. See
"Flash update procedures"
3. Replace component under
function test
No action
1. Flash system
2. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log
file
1. Make sure the component that
is called out is connected and/or
enabled. See
"Using the Setup
Utility,"
2. Re-run test
3. Replace the component that is
called out in warning statement
4. Replace the component under
test
1. If a component is called out,
make sure it is connected and/or
enabled. See
"Using the Setup
Utility,"
2. Flash the system and re-test. See
"Flash update procedures"
3. Go to
"Undetermined problems"
1. See
"Undetermined problems"
2. Flash the system and re-test. See
"Flash update procedures"
3. Replace component under
function test
1. Power supply
2. System board
1. Voltage Regulator Module (VRM)
2. Microprocessor
3. System board