Lenovo 3000 K100 Hardware Maintenance Manual page 48

Hide thumbs Also See for 3000 K100:
Table of Contents

Advertisement

Hardware Maintenance Manual

Diagnostic Error Code
071-04X-XXX
Audio port failure
071-195-XXX
Audio port Test aborted by user
071-196-XXX
Audio port test halt, error threshold
exceeded
071-197-XXX
Audio port test warning
071-198-XXX
Audio port test aborted
071-199-XXX
Audio port test failed, cause
unknown
071-25X-XXX
Audio port failure
080-000-XXX
Game Port interface Test Passed
080-XXX-XXX
Game Port interface Error
080-195-XXX
Game Port interface Test aborted by
user
080-196-XXX
Game Port interface test halt, error
threshold exceeded
FRU/Action
1. Run Setup
2. Audio card, if installed
3. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log
file
1. Make sure the component that
is called out is connected and/or
enabled. See
"Using the Setup
Utility,"
2. Re-run test
3. Replace the component that is
called out in warning statement
4. Replace the component under
test
1. If a component is called out,
make sure it is connected and/or
enabled. See
"Using the Setup
Utility,"
2. Flash the system and re-test. See
"Flash update procedures"
3. Go to
"Undetermined problems"
1. See
"Undetermined problems"
2. Flash the system and re-test. See
"Flash update procedures"
3. Replace component under
function test
1. Speakers
2. Audio card, if installed
3. System board
No action
1. Remove the game port device
and re-test the system
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log
file