Lenovo 3000 K100 Hardware Maintenance Manual page 35

Hide thumbs Also See for 3000 K100:
Table of Contents

Advertisement

Diagnostic Error Code
001-041-XXX
System DMA failure
001-195-XXX
System Test aborted by user
001-196-XXX
System test halt, error threshold
exceeded
001-197-XXX
System test warning
001-198-XXX
System test aborted
001-199-XXX
System test failed, cause unknown
001-250-XXX
System ECC error
001-254-XXX
001-255-XXX
001-256-XXX
001-257-XXX
System DMA error
001-260-XXX
001-264-XXX
System IRQ error
001-268-XXX
System IRQ1 failure
001-269-XXX
System IRQ2 failure
001-270-XXX
System IRQ3 failure
Chapter 6. Symptom-to-FRU Index
FRU/Action
1. Power-off/on system and re-test
2. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log
file
1. Make sure the component that
is called out is connected and/or
enabled. See
"Using the Setup
Utility,"
2. Re-run test
3. Replace the component that is
called out in warning statement
4. Replace the component under
test
1. If a component is called out,
make sure it is connected and/or
enabled. See
"Using the Setup
Utility,"
2. Flash the system and retest. See
"Flash update procedures"
3. Go to "Undetermined problems"
1. Go to
"Undetermined problems"
2. Flash the system and re-test
3. Replace component under
function test
System board
System board
System board
1. Device on IRQ1
2. System board
1. Device on IRQ2
2. System board
1. Device on IRQ3
2. System board


Hide quick links: