Diagnostic Error Code
005-197-XXX
Video test warning
005-198-XXX
Video test aborted
005-199-XXX
Video test failed, cause unknown
005-2XX-XXX
005-3XX-XXX
Video subsystem error
006-000-XXX
Diskette interface Test Passed
006-0XX-XXX
Diskette interface error
006-195-XXX
Diskette interface Test aborted by
user
006-196-XXX
Diskette interface test halt, error
threshold exceeded
006-197-XXX
Diskette interface test warning
FRU/Action
1. Make sure the component that
is called out is connected and/or
enabled. See
"Using the Setup
Utility,"
2. Re-run test
3. Replace the component called
out in warning statement
4. Replace the component under
test
1. If a component is called out,
make sure it is connected and/or
enabled. See
"Using the Setup
Utility,"
2. Flash the system and re-test. See
"Flash update procedures"
3. Go to
"Undetermined problems"
1. Go to
"Undetermined problems"
2. Flash the system and re-test. See
"Flash update procedures"
3. Replace component under
function test
1. Video card, if installed
2. System board
No action
1. Diskette drive Cable
2. Diskette drive
3. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log
file
1. If a component is called out,
make sure it is connected and/or
enabled
2. Re-run test
3. Replace the component that is
called out in warning statement
4. Replace the component under
test

Hide quick links: